A tolerance needs a reference
A nominal dimension is a target. Its tolerance states the acceptable variation. For a nominal 10.000 mm diameter, a tolerance of ±5 μm (±0.005 mm) permits a range from 9.995 to 10.005 mm: a total band of 0.010 mm. A total band of 5 μm (0.005 mm) is a different requirement. Always show the exact notation on the drawing.
Capability is feature-specific
A supplier’s smallest stated tolerance is not automatically achievable on every part. Material, size, feature shape, accessibility and process sequence all matter. Request confirmation for the actual geometry, rather than assuming the same limit applies to every dimension.
Dimensional and geometric controls differ
A diameter tolerance alone does not define how that diameter relates to another surface. Position, runout, perpendicularity and other relationships may need their own controls and datums. Use the drawing standard appropriate to your project and identify it clearly.
Finishing can change the result
Coatings add thickness; heat treatment can change size or shape. State whether the requirement applies before or after these processes. Critical masked surfaces and surfaces that must remain uncoated should be identified before quotation.
Make inspection part of the request
Ask how critical dimensions will be verified and what report you will receive. Agree the relevant measurement conditions, sampling and documentation requirements before the order. A complete requirement includes both the part and how acceptance will be assessed.
Send your drawing
for review.
Include the material, quantity and any critical requirements.
Request a quote